# Electric Actuated Butterfly Valve: Sizing and RFQ Guide

## **Quick Answer**

Electric actuated butterfly valve selection starts with valve torque at the worst differential pressure and temperature, then matches an actuator that can deliver it at the available power supply and required duty. On/off service, modulating control, fail-safe position, feedback and environment each change the specification. PANS butterfly valves are supplied with the actuator mounting interface defined for the selected model. State medium, pressure, temperature, cycle rate, power and control signal so both parts are sized together.

An electric actuator needs no compressed air, gives clear position feedback and connects to a plant control system. The hard part is not the motor: it is defining torque, duty and interface so valve, gearbox and actuator work as one assembly.

## What Parts Make Up an Electric Actuated Butterfly Valve?

An electric actuated butterfly valve combines a valve and an actuator, and each half carries its own selection data.

The valve side includes the body, disc, stem, seat and bearings. Wafer bodies fit between flanges, lugged bodies allow dead-end service, and double-flanged bodies give a defined envelope. The seat drives torque and temperature limits: resilient seats seal at low differential pressure but have a narrower temperature range. PTFE seats, such as the RPTFE seat in the [PANS high-performance butterfly valves](https://www.pansvalve.com/products/high-performance-butterfly-valve/), and metal seats in the metal-seated ranges extend temperature capability at the cost of higher seating force.

High Performance Butterfly Valve

Wafer, lug or flanged connections with RPTFE seat and electric actuation; sizes DN50–DN600 and pressure PN2.5–PN40.

[View Valve Data](https://www.pansvalve.com/products/high-performance-butterfly-valve/)[![Silver rectangular valve actuator with black caps mounted above a black butterfly valve whose silver disc is marked 12, 150LB and CF8M.](https://www.pansvalve.com/wp-content/uploads/2024/09/High-Performance-Butterfly-Valve.png)![Labeled diagram of an electric actuator above a butterfly valve body, calling out mounting interface and motor/gear housing; note to verify output drive, bracket and clearance.](https://www.pansvalve.com/wp-content/uploads/2024/09/High-Performance-Butterfly-Valve.png" style="width:100%;height:100%;object-fit:cover;display:block"&gt;](https://www.pansvalve.com/products/high-performance-butterfly-valve/)

The actuator side includes the motor, gear train, limit and torque switches, control card, terminal box and manual override. The gear train multiplies torque and sets stroke speed; the switches report position and protect against overload.

The halves meet at the mounting interface. ISO 5211 defines a flange pattern and shaft drive, but that alone does not prove a match. Output torque, shaft size, spool height and bracket clearance must be checked together. The [PANS butterfly valve range](https://www.pansvalve.com/butterfly-valve-manufacturer/) lists body styles; the model drawing remains the reference.